B. Clearances
WARNING! Risk of Fire!
YoumustcomplywithallminimumairspaceclearancestocombustiblesasspeciedinFigure3.2.DO NOT pack required
airspaceswithinsulationorothermaterials.Framingornishingmaterialusedonthefrontof,orinfrontof,thereplace
closer than the minimums listed must be constucted entirely of non-combustible materials (i.e., steel studs, concrete board,
etc.).Failuretocomplymaycausere.
Figure 3.2 Clearances to Combustible Materials
(ceiling)
(roof)
(ceiling)
2 in. (51 mm) min.
Attic
Insulation
Shield
Ceiling Firestop
(attic)
Storm Collar
Roof Flashing
2 in. min.
(51 mm)
2 in. (51 mm) min.
2 in. (51 mm) min.
Ceiling Firestop
Offset/Return with
hanger straps
2 in.
(51 mm)
min.
2 in. (51 mm) min.
Must have 2 in. (51 mm)
minimum clearance
to header
Electrical wires must be 3-1/2: (89mm)
from top
0 in. to level
of standoffs
1 in. (25mm) to side of appliance
1/2 in. (13 mm) to back
of appliance
0 in.
to floor
36 in. (914 mm)
standoffs to ceiling
Chimney Air Kit required with SL chimney
11
Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev G • 5/27/14