The 7100FP Fireplace will t a framed opening height of
45-7/8in.(1165mm)tallandwidthof42in.(1067mm).The
nishedcavitydepthmustbenolessthan24in.(610mm).
Framingmustextendstraightupallthewaytotheceiling.
Figure6.3showsatypicalframing(using2x4lumber)of
thereplace,assumingcombustiblematerialsareused.All
required clearances to combustibles around the replace
mustbeadheredto.SeeFigure6.2,onpreviouspage.Any
framingacross the topof thereplace must beabove the
levelofthetopstandoffs.(Norecessabovestandoffs.)
Figure 6.3 Framing the Fireplace
12 in.
(305mm)
42 in.
(1067mm)
45-7/8 in.
(1165mm)
24 in.
(610mm)
2 in.
(51mm)
Position
combustible/
non-combustible
mantel60in.
(1524mm)
frombaseof
thereplace
Non-combustible mantel material minimum height from
base of replace to underside of mantel 46 in. (1168mm)
when the following enclosure construction materials are
used:
Non-combustible framing materials must be used above
replace to height of 84 in. (2134mm) or to the ceiling
from base of replace for all construction materials,
framing members, sheeting, and all nish materials.
1. MINIMUM CLEARANCES TO COMBUSTIBLES
Materialswhichwillnotigniteandburn.Suchmaterialsare
thoseconsistingentirely ofsteel,iron, brick, tile,concrete,
slate,glassorplasters,oranycombinationthereof.
MaterialsthatarereportedaspassingASTME136,Stan-
dard Test Method for Behavior of Materials, in a Vertical
TubeFurnace at 750°C, shall beconsidered non-combus-
tiblematerials.
Materialsmadeoforsurfacedwithwood,compressedpa-
per,plantbers,plastics,orothermaterialsthatcanignite
andburn,whetherameproofedornot,orwhetherplastered
orun-plasteredshallbeconsideredcombustiblematerials.
3. NON-COMBUSTIBLE MATERIALS
4. COMBUSTIBLE MATERIALS
WITHIN ENCLOSURE AREA
Appliancetobackwall 1/2in.(13mm)
Appliancetosidewall 1in.(25mm)
Ductbootstoframing 0in.(0mm)
Topstandoffstoheader 0in.(0mm)
Dooropeningtosidewall 22-7/8in.(581mm)
EXPOSED SURFACES
Faceplatetosidewall 16in.(406mm)
Heatzoneairgrillstoceiling 12in.(305mm)
MANTEL
Mantelminimumheight 60in.(1524mm)
Maximummanteldepth 12in.(305mm)
Chimneysectionsatanylevelrequirea2in.(51mm)minimum
airspaceclearancebetweentheframingandchimneysection.