Quadra-Fire 7100FP Manuale del Proprietario

Navigare online o scaricare Manuale del Proprietario per Camini Quadra-Fire 7100FP. Quadra-Fire 7100FP Owner`s manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
R
www.quadrafire.com
433-1390G
September 1, 2008
DO NOT DISCARD THIS MANUAL
CAUTION
Important operating
and maintenance
instructions included.
Leave this manual with
party responsible for
use and operation.
• Read, understand and
follow these instructions
for safe installation and
operation.
DO NO
T
DISCARD
WARNING
If the information in these instruc-
tions is not followed exactly, a
fire may result causing property
damage, personal injury, or death.
Do not store or use gasoline or other flam
-
mable vapors and liquids in the vicinity of this
or any other appliance.
Do not overfire - If heater or chimney connec
-
tor glows, you are overfiring. Overfiring will
void your warranty.
Comply with all minimum clearances to com
-
bustibles as specified. Failure to comply may
cause house fire.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies recommends NFI certified profes-
sionals, or technicians supervised by an
NFI certified professional.
7100FP
EPA CERTIFIED WOODBURNING FIREPLACE
Owners Manual
Installation and Operation
7100FP-BK-B
7100FP-GD-B
7100FP-NL-B
Model:
Fire Risk.
WARNING
For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).
O-T L
Tested and
Listed by
Portland
Oregon USA
OMNI-Test Laboratories, Inc.
C
US
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
WARNING
Hot glass will cause burns.
Do not touch glass until it is cooled
• NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in the same room
as appliance
Alert children and adults to hazards of high
temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
combustibles away.
Vedere la pagina 0
1 2 3 4 5 6 ... 71 72

Sommario

Pagina 1 - Owner’s Manual

R www.quadrafire.com433-1390GSeptember 1, 2008DO NOT DISCARD THIS MANUALCAUTION• Important operating and maintenance instructions included.• Leave th

Pagina 2 - EPA CERTIFIED FIREPLACE

Page 10433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace3 Framing and Clearances A. Selecting Fireplace LocationSeveral options are availa

Pagina 3 - TABLE OF CONTENTS

September 1, 2008433-1390GPage 117100FP EPA Woodburning FireplaceR B. ClearancesFigure 11.1 Clearances to Combustible MaterialsFire Risk• Comply wi

Pagina 4 - Listing and Code Approvals

Page 12433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceC. Frame the FireplaceNOTE: Wiring for blowers must be done before framed enclosu

Pagina 5 - C. Glass Specifications

September 1, 2008433-1390GPage 137100FP EPA Woodburning FireplaceR Fire RiskDo not apply combustible finishing materials over any part of the front of

Pagina 6 - Getting Started

Page 14433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceE. Construct the ChaseA chase is a vertical boxlike structure built to enclose the

Pagina 7

September 1, 2008433-1390GPage 157100FP EPA Woodburning FireplaceR A. Install the Outside Air KitThis fireplace will operate correctly only if adequat

Pagina 8 - D. Typical Fireplace System

Page 16433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceRisk of Smoke SpillageOutside air inlet must be located to prevent blockage from:

Pagina 9 - E. Tools and Supplies Needed

September 1, 2008433-1390GPage 177100FP EPA Woodburning FireplaceR Figure 17.1 Outside Convection Air PlacementOutlet blocked bysnow, leaves, etc.NO

Pagina 10 - ABC D E FG H I

Page 18433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceThe auxiliary convection lever allows you to choose where the convection air is co

Pagina 11 - B. Clearances

September 1, 2008433-1390GPage 197100FP EPA Woodburning FireplaceR • Level the FireplaceLevel the fireplace side-to-side and front-to-back. Shim with

Pagina 12 - C. Frame the Fireplace

and Welcome to the Quadra-Fire Family!Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance

Pagina 13

Page 20433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceNOTE:• Chimney performance may vary.• Trees, buildings, roof lines and wind cond

Pagina 14 - Materials

September 1, 2008433-1390GPage 217100FP EPA Woodburning FireplaceR A. Chimney RequirementsVertical distances are measured from the base of the fire-pl

Pagina 15 - Installation of Fireplace

Page 22433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceC. Using Offsets/ReturnsTo bypass any overhead obstructions, the chimney may be of

Pagina 16

September 1, 2008433-1390GPage 237100FP EPA Woodburning FireplaceR D. Assemble the Chimney SectionsAttach either a straight chimney section or an off

Pagina 17

Page 24433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceF. Install the Ceiling Firestops• Mark and cut an opening in the ceiling for the

Pagina 18 - C. Convection Air Lock

September 1, 2008433-1390GPage 257100FP EPA Woodburning FireplaceR G. Install the Attic Insulation ShieldAn insulation shield must be installed when

Pagina 19 - D. Secure the Fireplace

Page 26433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace A Gas Termination Wood or Fuel Oil Termination B 6 in. (152 mm) min.

Pagina 20 - Chimney Assembly

September 1, 2008433-1390GPage 277100FP EPA Woodburning FireplaceR Figure 27.1 Ceiling/Attic ConstructionFire Risk• Must maintain 2 in. (51 mm) ai

Pagina 21 - Table 21.2

Page 28433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceNAILFLASHINGPLATECHIMNEYTHIMBLEEXTENSIONSCREWFLASHINGTHIMBLEADJUSTABLE EXTENSION H

Pagina 22 - Table 22.1

September 1, 2008433-1390GPage 297100FP EPA Woodburning FireplaceR Termination Cap Storm Collar Slope Downward Turn-down Drip Edge Chase (Chimney) 2

Pagina 23 - 300 Series

Section 1: Listing and Code ApprovalsA. Appliance Certification . ...4B. Mobile Home Approved ...4C. Glass Specifica

Pagina 24 - 4" Flex

Page 30433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceStorm Collar Flashing Collar Top of Pipe 14-1/2 in. (368mm) max. 1-1/2 in. (38 mm)

Pagina 25 - I. Secure the Chimney

September 1, 2008433-1390GPage 317100FP EPA Woodburning FireplaceR A. Blower Replacement 7 Replacement Parts Screwdriver SlotScrewsUnplug wire harne

Pagina 26 - Complete the Enclosure

Page 32433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceB. Baffle Removal and Installation1. Remove all ash from firebox, and extinguish a

Pagina 27

September 1, 2008433-1390GPage 337100FP EPA Woodburning FireplaceR This kit is tested and safe when installed in accordance with this installation ma

Pagina 28

Page 34433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceINSTALLATION1. Remove the knockout or cover plate from the top of the fireplace and

Pagina 29 - C. Chase Top

September 1, 2008433-1390GPage 357100FP EPA Woodburning FireplaceR NOTE: Secure the duct so that clearance to the fire-place outer wrap is maintained

Pagina 30

Page 36433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceRemove 2 screws and pry open access door.1. Remove both doors, fascia and brick.

Pagina 31 - Replacement Parts

September 1, 2008433-1390GPage 377100FP EPA Woodburning FireplaceR Timer PlateRotate assembly up and out through access doorArm must be in this posit

Pagina 32 - Left Door

Page 38433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace8 Finishing A. Hearth ExtensionA hearth extension must be installed with all firepl

Pagina 33

September 1, 2008433-1390GPage 397100FP EPA Woodburning FireplaceR Figure 39.1 Positioning the Protective Metal Hearth StripsFire Risk• Metal heart

Pagina 34 - Run Length Cut Pipe

Page 4433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace1 Listing and Code Approvals A. Appliance CertificationThis appliance is approved f

Pagina 35 - Fan Housing

Page 40433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceFascia Outer Can Flange Ember Strip (Seal gap with High temp, noncombustible seala

Pagina 36 - Be careful not to

September 1, 2008433-1390GPage 417100FP EPA Woodburning FireplaceR Seal with non-combustiblesealantC. Position the Hearth ExtensionPosition and se

Pagina 37 - F. Manual Timer Override

Page 42433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceTOOLS NEEDED: Powered drill with #2 Phillips head bit; caulk-ing gun.1in. (25mm) O

Pagina 38 - Finishing

September 1, 2008433-1390GPage 437100FP EPA Woodburning FireplaceR Figure 43.1 Mantel Specifications60 in.(1524mm)MantelClearances are from bottom of

Pagina 39 - 1041 508

Page 44433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace9 Operating Instructions Do not over-fire.Over-firing may ignite creosote or will da

Pagina 40 - . . . . . . . . . .

September 1, 2008433-1390GPage 457100FP EPA Woodburning FireplaceR C. General InformationFireplaces, as well as other woodburning appliances, have be

Pagina 41 - Seal with

Page 46433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceMoisture contentRegardless of which species of wood you burn, the single most impo

Pagina 42 - Super Calstick to

September 1, 2008433-1390GPage 477100FP EPA Woodburning FireplaceR Storing WoodSplitting wood before it is stored reduces drying time. The following

Pagina 43 - F. Mantel

Page 48433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceFor maximum operating efficiency with the lowest emissions, follow these operating

Pagina 44 - Operating Instructions

September 1, 2008433-1390GPage 497100FP EPA Woodburning FireplaceR I. Starting a FireBefore lighting your first fire in the fireplace, make cer-tain th

Pagina 45 - C. General Information

September 1, 2008433-1390GPage 57100FP EPA Woodburning FireplaceR Improper installation, adjustment, alteration, ser-vice or maintenance can cause in

Pagina 46 - Hardwood vs. Softwood

Page 50433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceCORRECT POSITIONINCORRECT POSITIONSFirebox damage due to improper baffle place-ment

Pagina 47 - E. Burning Process

September 1, 2008433-1390GPage 517100FP EPA Woodburning FireplaceR K. Outside AirA source of air (oxygen) is required in order for combustion to take

Pagina 48 - H. Burn Rates

Page 52433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceN. Blower OperationInstructions with Blower Override Switch in manual posi-tion.N

Pagina 49 - I. Starting a Fire

September 1, 2008433-1390GPage 537100FP EPA Woodburning FireplaceR 10 Troubleshooting This fireplace will operate correctly only if adequate ventila-t

Pagina 50 - INCORRECT POSITIONS

Page 54433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceAnother appliance in home also exhaustingair (furnace, fan, dryer, etc.)?Air regis

Pagina 51 - M. Glass Doors

September 1, 2008433-1390GPage 557100FP EPA Woodburning FireplaceR Diagnostic Question Possible Causes of Condition SolutionsAre the air controls ope

Pagina 52 - Q. Chimney Fire

Page 56433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace4. I don’t get enough/any heat. What can I do about it?Diagnostic Question Possi

Pagina 53 - Troubleshooting

September 1, 2008433-1390GPage 577100FP EPA Woodburning FireplaceR 11 Maintenance and Servicing the Fireplace A. General MaintenanceInspection: Ins

Pagina 54 - September 1, 2008

Page 58433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace2. Disposal of AshesFire Risk.Disposal of AshesWARNING• Ashes should be placed i

Pagina 55

September 1, 2008433-1390GPage 597100FP EPA Woodburning FireplaceR 4555 55555355555222224555311C. Brick ReplacementThe firebox of your fireplace is lin

Pagina 56

Page 6433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace2 Getting Started A. Design and Installation ConsiderationsC. Negative PressureDraf

Pagina 57 - A. General Maintenance

Page 60433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceE. Maintenance Task ListInspect Maintenance TasksScreens 1. Assess condition of sc

Pagina 58 - B. Glass Replacement

September 1, 2008433-1390GPage 617100FP EPA Woodburning FireplaceR Date of Service Performed By Description of ServiceF. Service And Maintenance Log

Pagina 59 - C. Brick Replacement

Page 62433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplace12 Reference Materials A. Fireplace DimensionsCLGHBlower Electric Access(right sid

Pagina 60 - E. Maintenance Task List

September 1, 2008433-1390GPage 637100FP EPA Woodburning FireplaceR B. Chimney ComponentsRF370 - Roof FlashingFlat to 6/12 Pitch12 in.(305 mm)24-5/8 i

Pagina 61 - Page 61

Page 64433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceAS8Straight AtticInsulation Shield24 in.(610 mmSL3 - Chimney StabilizerInside Diam

Pagina 62 - Reference Materials

September 1, 2008433-1390GPage 657100FP EPA Woodburning FireplaceR Figure 65.1 - Door, Glass & Door Handle Assembly303133632237386742334394034355

Pagina 63 - B. Chimney Components

Page 66433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceD. Fireplace DiagramFigure 66.1 - Fireplace Diagram1011121314151617181920252627212

Pagina 64 - 15-3/4 in

September 1, 2008433-1390GPage 677100FP EPA Woodburning FireplaceR IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on

Pagina 65

Page 68433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceItem #Part DescriptionAlphabetical OrderSKUOuter Can Cover Plate480-1300Outer Can

Pagina 66 - D. Fireplace Diagram

September 1, 2008433-1390GPage 697100FP EPA Woodburning FireplaceR G. Warranty PolicyHearth & Home Technologies LIMITED WARRANTYHearth & Home

Pagina 67 - E. Service Parts

September 1, 2008433-1390GPage 77100FP EPA Woodburning FireplaceR The 7100FP Fireplace requires a minimum flue draft of -0.10 inches of water column o

Pagina 68 - F. Accessories

Page 70433-1390GSeptember 1, 2008R 7100FP EPA Woodburning Fireplacemental conditions, inadequate ventilation or drafting caused by tight sealing cons

Pagina 69 - G. Warranty Policy

September 1, 2008433-1390GPage 717100FP EPA Woodburning FireplaceR This page intentionally left blank.

Pagina 70 - 4021-645A 09-01-08

R Hearth & Home Technologies1445 North HighwayColville, WA 99114Division of HNI INDUSTRIES433-1390GSeptember 1, 2008Page 72CONTACT INFORMATION:P

Pagina 71 - Page 71

Page 8433-1390GSeptember 1, 2008R 7100FP EPA Woodburning FireplaceFigure 8.1 Typical Fireplace SystemNote: Junction box should be installed during

Pagina 72 - Your Records for Model:

September 1, 2008433-1390GPage 97100FP EPA Woodburning FireplaceR Before beginning the installation be sure the following tools and building supplies

Commenti su questo manuale

Nessun commento