Quadra-Fire • QV36DC-A • 2161-900 • 4/081Model:QV36DC-AOwner’s ManualInstallation and Operation• Do not store or use gasoline or other fl am-mab
Quadra-Fire • QV36DC-A • 2161-900 • 4/0810Figure 1. Diagram of the QV36DC-ATOPSTANDOFFSHOODELECTRICALACCESSGASCONTROLSRATINGPLATE ANDLABELSGASL
Quadra-Fire • QV36DC-A • 2161-900 • 4/08113Installing the FireplaceStep 1. Locating the FireplaceThe following diagram shows space and clearance
Quadra-Fire • QV36DC-A • 2161-900 • 4/0812Framing should beconstructedof2X4lumber or heavier.Showscenter of 10” x12” vent framingholes for top a
Quadra-Fire • QV36DC-A • 2161-900 • 4/0813Figure 4. DVP-Series Direct Vent Component Specifi cations (5-inch inner pipe / 8-inch outer pipe)NOT
Quadra-Fire • QV36DC-A • 2161-900 • 4/0814Figure 5. Vent System Components and Termination KitsIdentifying Vent Components The vent systems ins
Quadra-Fire • QV36DC-A • 2161-900 • 4/0815Figure 6. Straight Up Vertical VentingSTRAIGHT UPVERTICAL VENTINGV (FT.)40’ MAX. (12.4 M)Flue Rest
Quadra-Fire • QV36DC-A • 2161-900 • 4/0816HORIZONTAL VENTINGKit No. H Max. RunDVP-TRAP 24” (610 mm)Figure 10. Corner InstallationNOTE: This mo
Quadra-Fire • QV36DC-A • 2161-900 • 4/0817 V H 1’ MIN. (305mm) 2’ MAX. (610mm) 2’ MIN. (610mm) 4’ MAX. (1.22m) 3
Quadra-Fire • QV36DC-A • 2161-900 • 4/0818Figure 13. Venting with Two 90° ElbowsVENTING WITH TWO (2) 90° ELBOWSV H H + H1 1´ MIN. (305 mm)
Quadra-Fire • QV36DC-A • 2161-900 • 4/0819Figure 15. Venting with three 90° elbowsVENTING WITH THREE (3) 90° ELBOWS1´MIN. (305mm) 2´MAX. (61
Quadra-Fire • QV36DC-A • 2161-900 • 4/082These units MUST use one of the vent systems described in the Installing the Fireplace section of the O
Quadra-Fire • QV36DC-A • 2161-900 • 4/0820VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.)1’ MIN. (305mm) 5’ MAX. (1.52m) 2’
Quadra-Fire • QV36DC-A • 2161-900 • 4/0821Venting Out the Top VentRemove the two screws in the top vent collar seal cap and remove the top vent
Quadra-Fire • QV36DC-A • 2161-900 • 4/0822Figure 19.HEATSHIELD3” MIN.(76 mm)COMBUSTIBLESURFACETo Install the Heat Shield:1. Determine if the hea
Quadra-Fire • QV36DC-A • 2161-900 • 4/08235. Install FirestopsFor Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall
Quadra-Fire • QV36DC-A • 2161-900 • 4/0824For Vertical Runs - One ceiling fi restop is REQUIRED at the hole in each ceiling through which the ven
Quadra-Fire • QV36DC-A • 2161-900 • 4/0825V= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINAL IS NOT PERMITTEDFigure 4.4 Minimum Clearanc
Quadra-Fire • QV36DC-A • 2161-900 • 4/0826For Vertical Terminations - To locate the vent and install the vent sections:• Locate and mark the ve
Quadra-Fire • QV36DC-A • 2161-900 • 4/0827Step 4. Positioning, Leveling, and Securing the Fireplace• Place the fi replace into pos
Quadra-Fire • QV36DC-A • 2161-900 • 4/0828• Insert insulation from the outside of the fi replace and pack the insulation tightly to totally seal
Quadra-Fire • QV36DC-A • 2161-900 • 4/0829Optional AccessoriesOptional fan and remote control kits require that 110-120 VAC be wired to the fact
Quadra-Fire • QV36DC-A • 2161-900 • 4/083TABLE OF CONTENTS Safety and Warning Information ...2Serv
Quadra-Fire • QV36DC-A • 2161-900 • 4/0830Step 9. FinishingFigure 36 shows the minimum vertical and corresponding maximum horizontal dimensions
Quadra-Fire • QV36DC-A • 2161-900 • 4/0831Figure 38. Figure 39. Figure 40. Figure 39. Figure 42. Position the right wall all the way to bac
Quadra-Fire • QV36DC-A • 2161-900 • 4/0832Placing the Ember Material• Release the four glass latches on the glass frame. Re-move glass door fro
Quadra-Fire • QV36DC-A • 2161-900 • 4/08331. Turn off all electric power to the appliance if service is to be performed.2. Open control access
Quadra-Fire • QV36DC-A • 2161-900 • 4/0834After the Installation LEAVE THIS INSTALLATION MANUAL WITH THE APPLIANCE FOR FUTURE REFER
Quadra-Fire • QV36DC-A • 2161-900 • 4/0835A. Standing Pilot Ignition SystemSymptom Possible Causes Corrective Action1. After repeated triggeri
Quadra-Fire • QV36DC-A • 2161-900 • 4/0836Troubleshooting (continued)Symptom Possible Cause Corrective Action3. Continued c. Defective valve. Tu
Quadra-Fire • QV36DC-A • 2161-900 • 4/0837Limited Lifetime WarrantyLIMITED LIFETIME WARRANTYThe Hearth & Home Technologies limited Lifetime
Quadra-Fire • QV36DC-A • 2161-900 • 4/0838Contact Information- NOTES -__________________________________________________________________________
Quadra-Fire • QV36DC-A • 2161-900 • 4/084Service Parts DiagramQV36DC-AService PartsRBeginning Manufacturing Date: Apr 2008 Ending Manufacturin
Quadra-Fire • QV36DC-A • 2161-900 • 4/085QV36DC-AIMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your app
Quadra-Fire • QV36DC-A • 2161-900 • 4/086Service Parts DiagramQV36DC-ARBeginning Manufacturing Date: Apr 2008 Ending Manufacturing Date:______
Quadra-Fire • QV36DC-A • 2161-900 • 4/0871Approvals and CodesAppliance Certifi cationThe fi replace model discussed in this Owner’s Manual has be
Quadra-Fire • QV36DC-A • 2161-900 • 4/088Requirements for the Commonwealth of MassachusettsFor all side wall horizontally vented gas fueled equi
Quadra-Fire • QV36DC-A • 2161-900 • 4/0892Getting StartedIntroducing Quadra-Fire Gas FireplacesQuadra-Fire direct vent gas fi replaces are design